NCK alarms
06/2009 Overview of alarms
2-23
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
4152 Illegal configuration of the 'Block display with absolute values' function
Definitions: The "Block display with absolute values" function has been illegally parameterized:
- An illegal block length has been set with MD28400 $MC_MM_ABSBLOCK:
While ramping up, the machine data will be checked for the following value range:
0, 1, 128 to 512
- An invalid display range has been set with MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[].
While ramping up, the machine data will be checked for the following upper and lower limits:
0 <= MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[0] <= 8
0 <= MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[1] <= (MD28060
$MC_MM_IPO_BUFFER_SIZE + MD28070$MC_MM_NUM_BLOCKS_IN_PREP).
Alarm 4152 is issued if the limits are violated.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure block length/display range within the permissible limits.
Program Con-
tinuation:
Switch control OFF - ON.
4160 [Channel %1: ] Invalid M function number configured for spindle
switchover
Parameters: %1 = Channel number
Definitions: An M function was specified in MD20094 $MC_SPIND_RIGID_TAPPING_M_NR in order to configure
the M function number for spindle switchover. The M function number is assigned by the system and
cannot be used for the switchover (M1 to M5, M17, M30, M40 to M45).
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure an M function which is not used by the system (M1 to M5, M17, M30, M40 to M45) in
MD20094 $MC_SPIND_RIGID_TAPPING_M_NR.
Program Con-
tinuation:
Switch control OFF - ON.
4181 [Channel %1: ] Invalid assignment of an M auxiliary function number
Parameters: %1 = Channel number
Definitions: In MD22254 $MC_AUXFU_ASSOC_M0_VALUE or MD22256 $MC_AUXFU_ASSOC_M1_VALUE, a
number has been specified for the configuration of a new predefined M function which is occupied by
the system, and cannot be used for an assignment. (M0 to M5, M17, M30, M40 to M45).
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure an M function in machine data MD22254 $MC_AUXFU_ASSOC_M0_VALUE or MD22256
$MC_AUXFU_ASSOC_M1_VALUE which is not occupied by the system (M1 to M5, M17, M30, M40
to M45).
Program Con-
tinuation:
Switch control OFF - ON.
4182 [Channel %1: ] Invalid M auxiliary function number in %2%3, MD reset
Parameters: %1 = Channel number
%2 = MD identifier
%3 = If required, MD index