Cycle alarms
06/2009 Overview of alarms
2-237
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61347 [Channel %1: ] Block %2: Angle 1st edge - 2nd edge equals 0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE961.
Remedy: Parameter _INCA equals 0.
61348 [Channel %1: ] Block %2: Angle rel. to reference edge equals 0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61349 [Channel %1: ] Block %2: Distance upper probe edge - measuring
position = 0 for tool radius measurement
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971.
Parameter _TP[x,9] distance between upper edge and lower edge of tool probe equals 0; relevant for
radius measurement.
Remedy: Check parameter _TP[x,9].
61350 [Channel %1: ] Block %2: feed, speed not programmed in _MFS for tool
measurement with rotating spindle
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971.
Measuring feed and/or spindle speed of tool measurement with rotating spindle in GUD variable
_MFS[2] not specified.
Remedy: Check parameter _MFS[2].
61351 [Channel %1: ] Block %2: Tool length or radius is 0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971.
For the active tool, the length or radius equal zero.
Remedy: Check length and radius of the active tool in the compensation data memory.
61352 [Channel %1: ] Block %2: Path for logfile not permitted
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The specified path for the log file is incorrect.
Remedy: Check parameter _PROTNAME[1].
61353 [Channel %1: ] Block %2: Path for logfile not found
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The specified directory does not exist or the specified path is incorrect.
Remedy: Check parameter _PROTNAME[1].