Cycle alarms
06/2009 Overview of alarms
2-233
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
and adjust _CVAL[0]/_CVAL[1] accordingly.
61314 [Channel %1: ] Block %2: Check selected tool type
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm is triggered: CYCLE971, CYCLE972, CYCLE982.
Remedy: Tool type impermissible for tool measurement/tool probe calibration.
61315 [Channel %1: ] Block %2: Check position of cutting edge
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm is triggered: CYCLE972, CYCLE973, CYCLE974, CYCLE982, CYCLE994.
Remedy: Check tool edge position (probe) in TO memory.
61316 [Channel %1: ] Block %2: Center and radius cannot be determined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No circle can be calculated from the measured points, as all measured points lie on a straight line.
The alarm is triggered by: CYCLE979
Remedy: Program change
61317 [Channel %1: ] Block %2: Check parameter CYCLE116
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameterization faulty; requires 3 or 4 points to calculate the center point. Alarm is triggered:
CYCLE979.
Remedy: Change parameterization of CYCLE116.
61318 [Channel %1: ] Block %2: Check weighting factor _K
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter _K is 0. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994,
CYCLE998.
Remedy: Check parameter _K.
61319 [Channel %1: ] Block %2: Check call parameter CYCLE114
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Internal error in measuring cycles. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE994, CYCLE998.
Remedy: Check call parameter CYCLE114.
61320 [Channel %1: ] Block %2: Check tool number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: With active tool management, parameter _TNUM=0 and parameter _TNAME is not set or
the specified tool name of tool management is unknown.
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy: Check parameter _TNUM, _TNAME.
61321 [Channel %1: ] Block %2: Check WO memory number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: WO with the number specified in _KNUM not existing. Alarm is triggered: CYCLE974, CYCLE977,
CYCLE978, CYCLE979, CYCLE994, CYCLE998.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameter _KNUM.