Overview of alarms 06/2009
Cycle alarms
2-198
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61025 [Channel %1: ] Block %2: Check tool carrier position
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: .
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61026 [Channel %1: ] Block %2: Cycle cannot be executed with NC function %4.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: .
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61099 [Channel %1: ] Block %2: Internal cycle error (%4)
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: .
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61101 [Channel %1: ] Block %2: Reference plane incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE71, CYCLE72, CYCLE81 to CYCLE90, CYCLE840,
SLOT1, SLOT2, POCKET1 to POCKET4, LONGHOLE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: With the relative specification of the depth, either different values for the reference plane and the
retraction plane must be selected or an absolute value must be specified for the depth.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61102 [Channel %1: ] Block %2: No spindle direction programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE86, CYCLE87, CYCLE88, CYCLE840, POCKET3,
POCKET4.
Reaction: Interpreter stop
NC Start disable in this channel.