NCK alarms
06/2009 Overview of alarms
2-85
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12553 [Channel %1: ] Block %2 name %3 option/function is not active
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions: The option (if MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 1) or the NC function (if
MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 3)
related to this language command is not active.
But the name of the language command is known.
Each programming of this language command is rejected with this alarm.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the "Compensation block" function by pressing the PROGRAM
CORRECT softkey. The cursor positions itself on the incorrect block.
- Correct the name used (in the case of a typing error).
- Activate the NC function (if a language command of an inactive function has been programmed).
- Enable the option required (if a language command of a function with a non-enabled option has been
programmed).
See also MD10711 $MN_NC_LANGUAGE_CONFIGURATION.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12555 [Channel %1: ] Block %2 function not available (identification %3)
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Fine ID
Definitions: The identifier has not been defined for this system.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC stop key and select the "Compensation block" function by pressing the "Program cor-
rect" softkey. The correction indicator will position in the incorrect block.
- Correct the name used (write error)
- Use a better software system in case of malfunction
- Check the definition of variables, subroutines and macros
- Declare a subroutine with EXTERNAL; load the subroutine to SPF-Dir
- Check the interface definition of the subroutine
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12556 [Channel %1: ] Block %2 name %3 Name is already known
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions: The name of the symbol to be created is part of the NC language scope and therefore already known.
Although the NC function is not active, this name can no longer be used for GUDs, macros and PROC
definitions.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press key NC Stop and select "Correction block" function by pressing softkey "Program correct". The
correction indicator is set to the incorrect block.
- Correct the name used (typing error)
- With MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 2 or 4, only those language commands
are created, the option of which has been set
or the function of which is active.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.