Overview of alarms 06/2009
NCK alarms
2-146
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: Program index [n] of the system variable $A_OUT [n] only between 0 and the value in MD10360
$MN_FASTIO_DIG_NUM_OUTPUTS.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17120 [Channel %1: ] Block %2 analog input no. %3 not activated
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Input number
Definitions: An attempt has been made by means of the system variable $A_INA[n] to read an analog input n that
has not been activated by the MD10300 $MN_FASTIO_ANA_NUM_INPUTS.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Modify part program or machine data
accordingly.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17130 [Channel %1: ] Block %2 analog output no. %3 not activated
Parameters: %1 = Channel number
%2 = Block number, label
%3 = No. of output
Definitions: An attempt has been made by means of the system variable $A_OUTA[n] to write or read an analog
output n that has not been activated by the MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Modify part program or machine data
accordingly.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17140 [Channel %1: ] Block %2 NCK output %3 is assigned to a function via
machine data
Parameters: %1 = Channel number
%2 = Block number, label
%3 = No. of output
Definitions: The programmed digital/analog output is assigned to an NC function (e.g. software cams).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Use another output or deactivate concur-
rent NC function via MD.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17150 [Channel %1: ] Block %2 maximum of %3 NCK outputs programmable in
the block
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Quantity
Definitions: No more than the specified number of outputs may be programmed in an NC block.
The quantity of hardware outputs is defined in the MDs:
MD10360 $MN_FASTIO_DIG_NUM_OUTPUTS and
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.