Overview of alarms 06/2009
Cycle alarms
2-260
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61800 [Channel %1: ] Block %2: Ext. CNC system missing
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Machine data for external language MD18800: $MN_MM_EXTERN_LANGUAGE or option bit 19800
$ON_EXTERN_LANGUAGE is not set.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61801 [Channel %1: ] Block %2: Wrong G code selected
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the program call CYCLE300<value> an impermissible numerical value was programmed for the
entered CNC System, or in the Cycles Setting Datum an incorrect value for the G Code System was
set.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61802 [Channel %1: ] Block %2: Wrong axis type
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed axis is assigned to a spindle
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61803 [Channel %1: ] Block %2: Programmed axis not available
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed axis is not in the system.
Alarm triggered by following cycles: CYCLE83, CYCLE84, CYCLE840.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameter _AXN.
Check MD20050-20080.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61804 [Channel %1: ] Block %2: Progr. position exceeds reference point
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed intermediate position or actual position is behind the reference point.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.