Overview of alarms 06/2009
NCK alarms
2-18
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Check axis configuration and enter the missing identifier into the MD or, should the axis not exist,
specify for this channel axis the machine axis 0 in the channel-specific MD20070
$MC_AXCONF_MACHAX_USED. If this concerns a geometry axis that is not to be used (this applies
only for 2-axis machining, e.g. on lathes), then channel axis 0 must be entered additionally in the chan-
nel-specific MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4032 [Channel %1: ] Wrong identifier for facing axis in %2
Parameters: %1 = Channel number
%2 = String: MD identifier
Definitions: According to the axis configuration in MD20150 $MC_GCODE_RESET_VALUES or MD20100
$MC_DIAMETER_AX_DEF, a facing axis identifier is expected at the specified location.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Add the correct identifier.
Program Con-
tinuation:
Switch control OFF - ON.
4040 [Channel %1: ] Axis identifier %2 not consistent with machine data %3
Parameters: %1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = There are not enough channel axes entered in the MD displayed.
Definitions: The use of the specified axis identifier in the displayed MD is not consistent the channel's axis config-
uration stated in the MD20070 $MC_AXCONF_MACHAX_USED and MD20050
$MC_AXCONF_GEOAX_ASSIGN_TAB.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Check and correct the identifier used in the MD10000 $MN_AXCONF_MACHAX_NAME_TAB,
MD20080 $MC_AXCONF_CHANAX_NAME_TAB and/or MD20060
$MC_AXCONF_GEOAX_NAME_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4045 [Channel %1: ] Conflict between machine data %2 and machine data %3
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = String: MD identifier
Definitions: Using the specified machine data %1 leads to a conflict with machine data %2.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct the specified machine data.
Program Con-
tinuation:
Switch control OFF - ON.
Komentáře k této Příručce