06/2009 List of action numbers
3-303
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
No. 63, PROGMODEDRYRUNON
No. 64, PROGMODEDRYRUNOFF
No. 65, BLOCKREADINHIBIT_ON
No. 66, BLOCKREADINHIBIT_OFF
No. 67, STOPATEND_ALARM
No. 68, STOP_ALARM
Explanation Activate test run (VDI signal: Rapid traverse override)
Cause 1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy − Wait until the preceding ASUB is complete or abort the program.
− Abort program
Explanation Deactivate test run (VDI signal: Rapid traverse override)
Cause 1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy − Wait until the preceding ASUB is complete or
− Abort program
Explanation Activate read-in disable for main run block (VDI signal: Read-in disable).
Cause -
Remedy -
Explanation Deactivate read-in disable for main run block (VDI signal: Read-in disable).
Cause -
Remedy -
Explanation Stop at block end (alarm)
Cause -
Remedy -
Explanation Stop all axes (alarm)
Cause -
Remedy -