61989 [Channel %1: ] Block %2: D1 is not programmed as active tool cutting
edge
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE73, CYCLE74, CYCLE75.
Remedy: --
62000 [Channel %1: ] Block %2: Insert new tool
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Please load new tool.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62100 [Channel %1: ] Block %2: No drilling cycle active
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No modal drilling cycle has been called before the drilling pattern cycle call. Alarm triggered by follow-
ing cycles: HOLES1, HOLES2.
Remedy: Check whether a drilling cycle was called prior to calling the drilling pattern cycle.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62101 [Channel %1: ] Block %2: Milling direction incorrect - G3 is generated
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Synchronous or reverse rotation programmed. But the spindle does not rotate at a cycle call.
Remedy: Check value in paramter CDIR.
62102 [Channel %1: ] Block %2: pocket not completely solidly machined during
finishing
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62103 [Channel %1: ] Block %2: No finishing allowance programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No finishing allowance is programmed, although it is necessary for this machining.
Reaction: Alarm display.
Remedy: Programm a finishing allowance.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62104 [Channel %1: ] Block %2: Drilling cycle incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
Komentáře k této Příručce