Overview of alarms 06/2009
NCK alarms
2-40
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Switch control OFF - ON.
8080 %1 option(s) is/are activated without setting the license key
Parameters: %1 = Number of non-licensed options
Definitions: One or more options were activated but no license key was set to prove the purchase of the option(s).
Reaction: Alarm display.
Remedy: Generate license key through the internet under http://www.siemens.com/automation/licence and
enter it in the operating area "Start-up", function (HSK) "Licences".
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
8081 %1 option(s) is/are activated that are not licensed by the license key
Parameters: %1 = Number of non-licensed options
Definitions: One ore more options were activated, that are not licensed by the license key entered.
Reaction: NC Start disable
Alarm display
Remedy: The unlicensed options included in the option screen can be licensed using a new License Key.
Licensing is described in the "Operator's Manual, Chapter: Licensing in SINUMERIK 802D sl".
Alternative: Cancel option
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
8082 A wrong license key was entered three times, Power On required before
next entry.
Definitions: The license key was entered wrongly at least three times. Before the next input, a new power ON is
required.
Reaction: NC Start disable
Alarm display
Remedy: Perform NCK-Power-ON and enter correct License Key.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
8100 [Channel %1: ] Block %2: function not possible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: - Impossible due to embargo regulations:
- 1. Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC, $AA_OVR,
$AA_VC and $AA_OFF) from synchronous actions as well as Continuous Dressing can be pro-
grammed only once in a block.
- 2. Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from synchronous
action' is not possible.
- 3. Axis interpolation: The number of axes interpolating with one another must not exceed 4 (this also
includes synchronous coupling of axes via synchronous actions "DO POS[X]=$A..." "DO
FA[X]=$A...").
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
10203 [Channel %1: ] NC start without reference point (action=%2<ALNX>)
Parameters: %1 = Channel number
%2 = Action number/action name
Definitions: NC start has been activated in the MDI or AUTOMATIC mode and at least one axis that needs to be
referenced has not reached its reference point.
Reaction: Interface signals are set.