Overview of alarms 06/2009
NCK alarms
2-88
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions: Max. nesting depth control structures (IF-ELSE-ENDIF, LOOP-ENDLOOP etc.) exceeded. At the
present time, the max. nesting depth is 8.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Correct part program. If necessary, move parts to a subroutine.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
12700 [Channel %1: ] Block %2 contour definition programming not allowed as
modal sub-programis active
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the external language mode, a block is programmed with contour definition and a modal cycle is
active at the same time. Because of unclear address assignment (e.g. R = radius for contour definition
or return plane for drilling cycle) contour definition programming must not be used when a modal cycle
is active.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12701 [Channel %1: ] Block %2 illegal interpolation type for contour definition
active
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In one contour definition block, G01 is not active as interpolation function. In one contour definition
block, the linear interpolation always has to be selected with G01. G00, G02, G03, G33 etc. are not
permitted.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program. Program linear interpolation G01.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12710 [Channel %1: ] Block %2 illegal language element in external language
mode
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed language element is not allowed or unknown in external language mode. Only the
language elements from Siemens mode which are used for subprogram calls (except for Lxx) and the
language constructs for program repetition with REPEAT (UNTIL) are allowed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Check that the language command is available in Siemens mode. Switch to Siemens mode with G290.
Program the command in the next block and switch back to the external language mode in the follow-
ing block.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12720 [Channel %1: ] Block %2 program number for macro call (G65/G66)
missing
Parameters: %1 = Channel number
%2 = Block number, label