Siemens SINUMERIK 802D sl Návod k obsluze Strana 272

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 340
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 271
Overview of alarms 06/2009
Cycle alarms
2-272
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
62312 [Channel %1: ] Block %2: probe is not perpendicular to plane!
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62313 [Channel %1: ] Block %2: The number of lines per page _PROTFORM[0]
is incorrect and is automatically adjusted.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycle: CYCLE106.
Remedy: Check _PROTFORM[0] in the program.
62314 [Channel %1: ] Block %2: Traverse path limitation via software end
position, collision detection activated, continue with NC START / cancel
with RESET.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE977
Remedy: Position the workpiece to be measured further away from the software end positions.
62315 [Channel %1: ] Block %2: Overwrite swivel data record TCARR = %4, yes
-> NC start, no -> reset
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy:
62316 [Channel %1: ] Block %2: Overwrite TRAORIdata, yes -> NC start, no ->
reset
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy:
62317 [Channel %1: ] Block %2: Tolerance of the linear vector %4 exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy:
62318 [Channel %1: ] Block %2: Tolerance of the rotary axis vector %4
exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy:
62500 [Channel %1: ] Block %2: GWPS has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy: Check the limit value for GWPS and program a lower value in the NC program if necessary