Cycle alarms
06/2009 Overview of alarms
2-209
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61176 [Channel %1: ] Block %2: text length _DF programmed too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The text length in the engraving cycle is too short. This means that the text for engraving is longer than
the specified text length.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter longer text length
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61177 [Channel %1: ] Block %2: polar text length > 360 degrees
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the engraving cycle, the polar text length must not exceed 360 degrees.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter shorter text length.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61178 [Channel %1: ] Block %2: code page not present
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified code page is not supported by the cycle.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Use code page 1252.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61179 [Channel %1: ] Block %2: character does not exist, no.: %4
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Character number
Definitions: The character entered in the text for engraving cannot be milled.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter another character.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61180 [Channel %1: ] Block %2: no name assigned to swivel data block,
although MD $MN_MM_NUM_TOOL_CARRIER > 1
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Although there are several swivel data blocks, no unique names have been assigned. Alarm triggered
by following cycles: CYCLE800.
Remedy: Assign unique names for swivel data blocks.