Overview of alarms 06/2007
NCK alarms/ISO alarms
2-100
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12460 Channel %1 block %2 maximum number of symbols exceeded with %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: The max. number of variable definitions, cycle programs and/or cycle parameters that the controller's
data management system is able to handle has been exceeded.
If this alarm occurs in conjunction with alarm 15175 (cycles were loaded again), not enough memory
is available. This situation can be remedied by modifying the machine data.
If this alarm occurs in conjunction with alarm 15180 (initial.ini download failed), then this alarm shows
the name of the block causing the error.
(For a list of names and their meaning -> please refer to alarm 6010)
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
Reduce the symbols in the block (possibly by using the array technique or by using R parameters), or
adapt the machine data (if you have access rights).
GUD data blocks can only cause errors as part of the 'initial.ini download' process.
Cycle program definitions will be reloaded for each Power On/NC-RESET. Thus, the modules can
cause errors only in conjunction with this action.
See also the explanations for alarm 6010.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12470 Channel %1 block %2 G function %3 is unknown
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: In the displayed block, a non-defined G function has been programmed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
You should decide on the basis of the machine manufacturer's programming guide whether or not the
displayed G function exists or is available, or whether a standard G function has been reconfigured.
Remove G function from the part program or program function call in accordance with the machine
manufacturer's programming guide.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12475 Channel %1 block %2 invalid G function number %3 programmed
Parameters: %1 = Channel number.
Definitions: %2 = Block number, label.
%3 = G code number.
A non-allowed G function number (parameter 3) has been programmed for a G group with indirect G
code programming.
Only the G function numbers indicated in the Programming Guide "Fundamentals", Section 12.3 "List
of G functions/Path conditions" are allowed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.