Overview of alarms 06/2007
NCK alarms/ISO alarms
2-154
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
15122 Power ON after power failure: %1 data were restored, of which %2
machine data, %3 errors.
Parameters: %1 = Number of data
%2 = Number of machine data
%3 = Number of errors occurred
Definitions: Notification alarm. The alarm has no negative effect as long as %3 the number of errors occurred is
zero.
%1 indicates the number of elementary and complex data restoring steps which were taken after a
power OFF during power ON orduring a power failure to restore the persistent NCK data.
%2 indicates the number of restored machine data. If the value is larger than zero, another warm
restart (NCK reset) may be necessary to make the - possibly configuring - machine data changes prior
to the power failure effective.
%3 indicates the number of errors occurred during data restoring.
Reaction: Alarm display.
Remedy: As long as %3 number of errors occurred is zero, the alarm is only informative.
As long as %3 number of errors is larger than zero, the alarm indicates a software error.
Continuing with the data is not recommended.
Please install a suitable archive file before continuing to avoid follow-up problems.
Please inform authorized personnel/service.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15150 Channel %1 block %2 reload from external aborted
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The processing of extern has been terminated because the reload buffer does not contain sufficient
machine function blocks (traversing blocks, auxiliary function, delay time, etc.). Background: When
already executed machine function blocks are released, memory becomes available in the reload
buffer. If machine function blocks are no longer released, nothing can be reloaded - this results in a
deadlock situation.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Add machine function blocks to the part program.
Increase the size of the reload buffer (MD 18360 MM_EXT_PROG_BUFFER_SIZE).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15160 Channel %1 block %2 wrong preprocessing configuration
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The following deadlock has been found in the interpreter:
A block element is needed but the block element memory is empty and there is no likelihood of getting
new block elements by processing the preprocessing/main run queue because this queue itself is
empty.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program