Overview of alarms 06/2007
NCK alarms/ISO alarms
2-152
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
14900 Channel %1 block %2 center point and end point programmed
simultaneously
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: When programming a circle by means of the opening angle, the circle center point was programmed
together with the circle end point. This is too much information for the circle. Only one of the two points
is allowed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Select the programming variant for which the dimension can be reliably taken from the workpiece des-
ignation (avoidance of conversion errors).
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14910 Channel %1 block %2 invalid angle of aperture for programmed circle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: When programming a circle by means of the opening angle, a negative opening angle or an opening
angle greater than or equal to 360 degrees has been programmed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program opening angle within the allowed range of values between 0.0001 and 359.9999 [degrees].
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14920 Channel %1 block %2 intermediate point of circle incorrect
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: When programming a circle by means of an intermediate point all 3 points (start, end and intermediate
points) are on a straight line and the intermediate point (programmed by means of interpolation param-
eters I, J, K) is not located between the start and end points.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Locate the position of the intermediate point with the parameters I, J and K in such a way that it actually
is located between the start and end points of the circle or do not make use of this type of circle pro-
gramming and instead program the circle with radius or opening angle or center point parameters.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
15030 Channel %1 block %2 different measurement system settings
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The INCH or METRIC instruction describes the system of measurement in which the data blocks have
been read from the control.
In order to prevent the incorrect interpretation of data intended for a particular system of measure-
ment, a data block is only accepted if the above instruction matches the active system of measure-
ment.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Change the system of measurement or load a data block which matches the system of measurement.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Komentáře k této Příručce