Cycle alarms
06/2007 Overview of alarms
2-317
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61711 Channel %1 block %2: Name of stock removal program missing
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61712 Channel %1 block %2: Tool parameter for machining direction not
defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61766 Channel %1 block %2: Error in blank program
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61798 Channel %1 block %2: Acknowledgment error ACTIVATE
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61799 Channel %1 block %2: Acknowledgment error READYPROG
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --