NCK alarms/ISO alarms
06/2007 Overview of alarms
2-49
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
6692 Cycle %1 lost
Parameters: %1 = Name of cycle
Definitions: A cycle has been changed and due to a power failure, the backup on the PC card could not be termi-
nated properly. The cycle is lost.
Reaction: NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Import the cycle again.
Program Con-
tinuation:
Switch control OFF - ON.
6693 File %1 lost
Parameters: %1 = file name
Definitions: Due to a power failure, a file change could not be terminated properly. The file is lost.
Reaction: NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Import the file again.
Program Con-
tinuation:
Switch control OFF - ON.
6698 Unknown NC card (%1/%2). Writing not possible.
Parameters:
Definitions: The NC card cannot be accessed because a valid write algorithm is not available for the flash memory.
Reaction: Alarm display.
Remedy: Use a compatible NC card or enter the new manufacturer code/device code in MD 11700
PERMISSIVE_FLASH_TAB after consultation with SIEMENS.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
7500 Block %1 invalid protection level for command %2 (protection level act.:
%3 prog.: %4)
Parameters: %1 = block number
%2 = programmed command
%3 = current protection level of command
%4 = programmed protection level of command
Definitions: During assignment of a protection level to a part program command using the REDEF command,
an non-permitted part program command was programmed
a protection level was programmed with a logically smaller number
(higher value) that the protection level that currently applies to this
command.
the relevant definition file does not possess sufficient write protection. The write protection for the file
must be at least as high as the highest protection level that is assigned to part program command in
his definition file.
Reaction: Alarm display.
Remedy: Correct the definition files /_N_DEF_DIR/_N_MACCESS_DEF or
/_N_DEF_DIR/_N_UACCESS_DEF. The language commands that are permissible for the relevant
system configuration are given in the Siemens Programming Guide or in the Manufacturer's documen-
tation.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program