Overview of alarms 06/2007
Cycle alarms
2-308
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61505 Channel %1 block %2: retraction path < 1mm
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE420
Remedy: Increase retraction path
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61506 Channel %1 block %2: infeed path < 1mm
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE420
Remedy: Increase infeed path
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61507 Channel %1 block %2: safety clearance < 1mm
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61508 Channel %1 block %2: Incorrect default setting for shoulder position
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61509 Channel %1 block %2: Incorrect default setting for dresser position
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61510 Channel %1 block %2: Test run feed is active
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE413,
CYCLE415, CYCLE420
Remedy: Switch off test run feed
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61511 Channel %1 block %2: Incorrect shoulder position or tool edge D1/D2
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program