NCK alarms/ISO alarms
06/2007 Overview of alarms
2-167
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: An attempt was made to activate more generic couplings than are configured in MD18450.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Reduce the number of defined or active couplings, or increase the number of coupling modules con-
figured in MD18450.
If necessary, buy another option stage of the generic coupling.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16671 Channel %1 block %2 following axis/spindle %3 maximum number of CP
modules (%4) has been exceeded
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP modules
Definitions: An attempt was made to activate more generic couplings than are configured in MD18450.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Reduce the number of defined or active couplings, or increase the number of coupling modules con-
figured in MD18450.
If necessary, buy another option stage of the generic coupling.
Program Con-
tinuation:
Clear alarm with the RESET key in all channels. Restart part program.
16672 Channel %1 block %2 leading axis/spindle %3 maximum number of CP
master values (%4) exceeded
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP master values
Definitions: An attempt was made to activate more master values of generic couplings than are configured in
MD18452.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Reduce the number of defined or active master values, or increase the total number of master values
configured in MD18452.
If necessary, buy another option stage of the generic coupling.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16673 Channel %1 block %2 leading axis/spindle %3 maximum number of CP
master values (%4) exceeded
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP master values
Definitions: An attempt was made to activate more master values of generic couplings than are configured in
MD18452.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Reduce the number of defined or active master values, or increase the total number of master values
configured in MD18452.
If necessary, buy another option stage of the generic coupling.