NCK alarms/ISO alarms
06/2007 Overview of alarms
2-127
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
14130 Channel %1 block %2 too many initialization values given
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: On assigning an array by means of SET, more initialization values than existing array elements have
been specified in the program run.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Reduce the number of initialization values.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14140 Channel %1 block %2 position programming without transformation not
allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Position information was programmed for an axis position but no transformation was active.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify the program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14144 Channel %1 block %2 PTP movement not allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The PTP G code was programmed for a movement other than G0 or G1.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify the program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14146 Channel %1 block %2 CP or PTP movement without transformation not
allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The CP or PTP G code was programmed for a movement but no transformation was active.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify the program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14157 Channel %1 block %2 illegal interpolation type with MOVT
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Linear or spline interpolation must be active with MOVT (G0, G1, ASPLINE, BSPLINE, CSPLINE).
Reaction: Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.