Overview of alarms 06/2007
NCK alarms/ISO alarms
2-140
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
14603 Channel %1 block %2 timeout during execution from external source.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: If a program is selected for execution from external source, it will be expected that the first part pro-
gram line can be read from the reload buffer within 60s after part program start.
Otherwise, part program processing will be aborted with alarm 14603 due to the assumption that the
connection to the HMI or the external device is faulted.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check the connection to the HMI and repeat selection of the program that is to be executed from exter-
nal source.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
- Acknowledge the alarm by pressing the RESET key
- Repeat program selection
- Start the part program
14610 Channel %1 block %2 compensation block not possible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An alarm was output which could be eliminated basically via program correction. Since the error
occurred in a program which is processed from external, a compensation block/program correction is
not possible.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Abort program with reset.
• Correct program on MMC or PC.
• Restart reloading (possibly with block search for interrupt location).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14615 Channel %1 An error occurred while handling the function syntax check:
identifier %3
Parameters: %1 = Channel number
%2 = Block number
%3 = Error code
Definitions: An error occurred while handling the function syntax check via the PI services _N_CHKSEL,
_N_CHKRUN, _N_CHKABO and _N_SEL_BL. Parameter %3 describes the error situation more
closely:
Value
1: An invalid line number was transferred with the PI service _N_SEL_BL
2: An invalid line number for the range end was transferred with the PI service _N_CHKRUN
3: PI service _N_CHKSEL was activated although a block selection (PI service _N_SEL_BL) was
active for the selected program.
Reaction: Alarm display.
Remedy: Value
1: Supply PI service _N_SEL_BL with the correct line number
2: Supply PI service _N_CHKRUN with the correct line number for the range end
3: Ensure that the channel is in reset status before activating the PI service _N_CHKSEL.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.