NCK alarms/ISO alarms
06/2007 Overview of alarms
2-197
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
16961 Channel %1 action %2<ALNX> prohibited during syntax check.
Parameters: %1 = Channel number
%2 = Action number/action name
Definitions: The function (2nd parameter) must not be activated during the syntax check.
Comment: The syntax check is served by the following PI services:
_N_CHKSEL _N_CHKRUN _N_CHKABO
Reaction: Alarm display.
Remedy: Wait for the end of the syntax check, or
Cancel the syntax check with reset, or
Cancel the syntax check with PI _N_CHKABO.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
16962 Channel %1 NCK computing time reduced, start is not allowed.
Parameters: %1 = Channel number
Definitions: The computing time available to the NCK has been reduced, starts have therefore been locked. The
computer performance is inadequate for smooth program execution. The computing time of the NCK
may have been reduced by the HMI because of an HMI part program simulation.
Reaction: Alarm display.
Remedy: Wait for the simulation to end or press RESET in any channel.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
17000 Channel %1 block %2 maximum number of symbols exceeded
Parameters: %1 = channel number
%2 = block number, label
Definitions: The maximum number of symbols defined by machine data 28020 MM_NUM_LUD_NAMES_TOTAL
has been exceeded.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
• Edit machine data
• Reduce the number of symbols (variables, subroutines, parameters)
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
17001 Channel %1 block %2 no memory left for tool/magazine data
Parameters: %1 = channel number
%2 = block number, label
Definitions: The quantity of tool data in the NC is limited.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Delete any unnecessary tools.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17010 Channel %1 block %2 no memory left
Parameters: %1 = channel number
%2 = block number, label
Definitions: When executing/reading files from the active working memory, it was found that there is not enough
memory space (e.g. when creating tool offset memory).
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Make more memory available to the data management system for subroutine calls and tool offsets