NCK alarms/ISO alarms
06/2007 Overview of alarms
2-115
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: State a directory that remains permanently loaded in the NCK as the target for the WRITE command
(e.g. MPF_DIR).
The alarm can be suppressed with machine data 11415 / $MN_SUPPRESS_ALARM_MASK_2 bit 8.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
14009 Channel %1 block %2 illegal program path %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Program path
Definitions: The part program command CALLPATH was called with a parameter (program path) referring to a
directory which does not exist in the file system of the NCK.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify the CALLPATH instruction such that the parameter contains the complete path name of the
loaded directory.
Load the programmed directory in the file system of the NCK.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14010 Channel %1 block %2 invalid default parameter in subroutine call
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In a subroutine call with parameter transfer, parameters have been omitted that cannot be replaced
by default parameters (call-by-reference parameters or parameters of type AXIS. The other missing
parameters are defaulted with the value 0 or with the unit frame in the case of frames).
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: The missing parameters must be provided with values in the subroutine call.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14011 Channel %1 block %2 program %3 not existing or will be edited
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions: The called program (main program or subroutine) has been called from the currently running part pro-
gram (main program or subroutine). Either it is not present in the NC memory or the option for the
associated function is not set.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Correct the NC part program.
1.Check the subroutine name in the calling program.
2.Check the name of the calling program.
3.Check whether the program has been transferred to the NC memory.
4.Check or set/correct the options.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14012 Channel %1 block %2 maximum subroutine level exceeded
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The maximum nesting depth of 8 program levels has been exceeded.
Subroutines can be called from the main program, and these in turn may have a nesting depth of 7.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.