61114 Channel %1 Block %2: Machining direction G41/G42 incorrectly defined
Parameters:
Definitions: Source (cycle):
CYCLE72
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The machining direction of the cutter radius compensation G41/G42 has been incorrectly selected.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61115 Channel %1 Block %2: Approach or retract mode(straight / circle / plane /
space) incorrectly defined
Parameters:
Definitions: Source (cycle):
CYCLE72
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: An incorrect contour approach or retract mode was defined; check parameter _AS1 or _AS2.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61116 Channel %1 Block %2: Approach or retract path = 0
Parameters:
Definitions: Source (cycle):
CYCLE72
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The approach or retract path is set to zero, it must be increased; check parameter _LP1 and/or _LP2.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61117 Channel %1 Block %2: Active tool radius <= 0
Parameters:
Definitions: Source (cycle):
CYCLE71
POCKET3
POCKET4
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The radius of the active tool is negative or zero. This is not permitted.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61118 Channel %1 Block %2: Length or width = 0
Parameters:
Definitions: Source (cycle):
CYCLE71
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.