400015 PROFIBUS DP: I/O defect: log adr. [x] bus adr./slot: [y/z]
Definitions: The PLC-AWP is using peripheral addresses which are not available.
[x]Logical I/O address
[y]Bus address (slave)
[z]Slot number
Error causes:
PROFIBUS peripheral has no voltage
Slave bus address set incorrectly
PROFIBUS connection faulty
Active MD 11240 (SDB PROFIBUS configuration) is set incorrectly
Reaction: PLC Stop
Remedy: Rectify the error using the error cause
Program Con-
tinuation:
Switch control OFF - ON.