NCK alarms/ISO alarms
06/2007 Overview of alarms
2-129
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: If tool compensation (G43/G44) is activated in the ISO M language mode, the linear type of interpola-
tion must be active.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Change part program
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14180 Channel %1 block %2 H number %3 is not defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified H number is not assigned to any tool (ISO M).
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Change part program
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14185 Channel %1 block %2 D number %3 is not defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified D number is not assigned to any tool (ISO M).
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Change part program
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14190 Channel %1 block %2 H number with G49
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: G49 (select tool length compensation) and an H word not equal to H0 have been programmed simul-
taneously.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Change part program
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.