Overview of alarms 06/2007
NCK alarms/ISO alarms
2-188
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
16927 Channel %1 action %2<ALNX> at active interrupt treatment not allowed
Parameters: %1 = channel number
%2 = action number/action name (see Section 1.5 Action List)
Definitions: This action may not be activated during interrupt processing (e.g. mode change).
Reaction: Alarm display.
Remedy: Reset or wait until interrupt processing is terminated.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
16928 Channel %1 interrupt treatment: action %2<ALNX> not possible
Parameters: %1 = channel ID
%2 = action number/action name (see Section 1.5 Action List)
Definitions: A program interrupt has been activated in a non REORG capable block.
Examples of possible program interrupts in this case:
- Travel to fixed stop
- VDI channel delete distance to go
- VDI axial delete distance to go
- Measuring
- Software limit
- Axis replacement
- Axis is exited follow-up mode
- Servo disable
- Gear stage change with actual GS does not match setpoint GS
The relevant block is a:
a collection block for block search (except for last collection block) the Overstore Off block.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Do not trigger the event on this block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
16930 Channel %1: preceding block and current block %2 must be separated
through an executable block
Parameters: %1 = channel number
%2 = block number
Definitions: The language function MSG must be packed into separate NC blocks. In order to prevent dips in
velocity, these blocks are appended to the following NC block by an internal NC function (with
WAITMC to the preceding NC block). For this reason, there must always be an executable block (not
a calculation block) between the NC blocks.
An executable NC block always includes e.g. travel movements, an auxiliary function, Stopre, dwell
time, etc.
Reaction: Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy: Program an executable NC block between the previous and the current NC block.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.