Siemens SINUMERIK 802D sl Specifikace Strana 219

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 392
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 218
NCK alarms/ISO alarms
06/2007 Overview of alarms
2-219
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
20050 Channel %1 axis %2 handwheel mode active
Parameters: %1 = channel number
%2 = axis name, spindle number
Definitions: The axes cannot be traversed in JOG mode using the traversing keys because traversing is still taking
place via the handwheel.
Reaction: Alarm display.
Remedy: Decide whether the axis is to be traversed by means of the direction keys or via the handwheel. End
handwheel mode, with axial deletion of distance to go (V 380x0002.2) if appropriate.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
20051 Channel %1 axis %2 handwheel mode not possible
Parameters: %1 = channel number
%2 = axis name, spindle number
Definitions: The axis is already traveling via the traversing keys, so handwheel mode is no longer possible.
Reaction: Alarm display.
Remedy: Decide whether the axis is to be traversed by means of the direction keys or via the handwheel.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
20052 Channel %1 axis %2 already active
Parameters: %1 = channel number
%2 = axis name, spindle number
Definitions: The axis is to traverse as a machine axis in JOG mode via the direction keys on the machine control
panel. However, this is not possible because:
it is already traversing as a geometry axis
(V32001000.6V32001000.7,
V32001004.6V32001004.7 or
V32001008.6V32001008.7)
it is already traversing as a machine axis
(V38000004.6V38000004.7) or
a frame is valid for a rotated coordinate system and another geometry axis involved in this is already
traversing in JOG mode by means of the direction keys.
Reaction: Alarm display.
Remedy: Stop traversing through the channel or axis interface or stop the other geometry axis.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
20053 Channel %1 axis %2 DRF, FTOCON, external zero point offset not
possible
Parameters: %1 = channel number
%2 = axis name, spindle number
Definitions: The axis is traversed in a mode (e.g. referencing) that allows no additional overlaid interpolation.
Reaction: Alarm display.
Remedy: Wait until the axis has reached its reference position or terminate reference point approach with
"Reset" and start DRF once again.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
20054 Channel %1 axis %2 wrong index for indexing axis in JOG mode
Parameters: %1 = channel number
%2 = axis name, spindle number
Definitions: 1. The displayed indexing axis is to be traversed incrementally in JOG mode (by 1 indexing position).
However, no further indexing position is available in the selected direction.
Zobrazit stránku 218
1 2 ... 214 215 216 217 218 219 220 221 222 223 224 ... 391 392

Komentáře k této Příručce

Žádné komentáře