Overview of alarms 06/2007
NCK alarms/ISO alarms
2-232
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
20144 Channel %1 block %2 motion synchronous action: system variable
access not possible
Parameters: %1 = Channel number
%2 = Block number
Definitions: When using system variables, it is assumed that a read/write operation can access the required data
successfully. In accesses to encoder actual values or digital I/Os, the result depends on the availability
of the corresponding hardware components. If an access within synchronized actions does not return
a valid value, alarm 20144 is output. Outside synchronized actions, such a read/write access causes
block execution to be interrupted until the result is available. Block execution is subsequently contin-
ued.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Before reading/writing system variables, ensure that it is possible to access the required hardware
components.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
20145 Channel %1 block %2 motion synchronous action: arithmetic error
Parameters: %1 = Channel number
%2 = Block number
Definitions: In calculating an arithmetic expression for a motion synchronous action, an overflow has occurred
(e.g. division by zero).
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct error in expression.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
20146 Channel %1 block %2 motion synchronous action: nesting depth
exceeded
Parameters: %1 = Channel number
%2 = Block number
Definitions: For calculating arithmetic expressions in motion synchronous blocks, an operand stack with a fixed
set size is used. With very complex expressions, this stack can overflow.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct error in expression.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
20147 Channel %1 block %2 motion synchronous action: command not
executable
Parameters: %1 = Channel number
%2 = Block number
Definitions: One of the commands for the synchronous action block cannot be executed, e.g. it is not possible to
perform a Reset to the synchronous action.
Measurement level 2
- Embargo version does not allow measurement from a synchronized action
- MEASA was programmed in a synchronized action
- Measurement is already active