Cycle alarms
06/2007 Overview of alarms
2-289
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61214 Channel %1 block %2: No lead programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No lead/helical lead has been entered.
Alarm triggered by following cycles: E_CR_HEL, E_PO_CIR, E_PO_REC, F_PO_CIR, F_PO_REC.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program a lead.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61216 Channel %1 Block %2: Feed/tooth only possible with cutting tools
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Feed per tooth is only possible with milling tools.
Alarm triggered by following cycles: E_TFS, F_TFS.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: As alternative, set a different feed type.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61217 Channel %1 Block %2: Cutting speed programmed for tool radius 0
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: To be able to work with cutting speed, the tool radius has to be specified.
Alarm triggered by following cycles: E_DR_SIN, E_DR_TAP, E_TFS, F_DR_SIN, F_DR_TAP,
F_DRILLC, F_DRM_TA, F_TAP, F_TFS
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter a value for cutting speed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61218 Channel %1 Block %2: Feed/tooth programmed, but number of tools
equals zero
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: For feed per tooth, the number of teeth has to be specified.
Alarm triggered by following cycles: E_TFS, E_DR_BGF, F_TFS.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter the number of teeth on the milling tool in the "Tool list" menu.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61219 Channel %1 Block %2: Tool radius too large
Parameters: %1 = Channel number
%2 = Block number, label
Zobrazit stránku 288