NCK alarms/ISO alarms
06/2007 Overview of alarms
2-161
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
15910 Channel %1 block %2 touch probe not allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: A non-existent touch probe for measuring without deletion of remaining distance has been selected in
the part program.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
15950 Channel %1 block %2 no traverse motion programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the part program, measurement with deletion of remaining distance without axis details has been
selected or the programmed traversing motion is zero.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
15960 Channel %1 block %2 no traverse motion programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the part program, measurement without deletion of remaining distance without axis details has been
selected or the programmed traversing motion is zero.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16000 Channel %1 block %2 invalid value for lifting direction
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: During the "rapid lift from contour" (keyword: LIFTFAST), a code value for the lifting direction (key-
word: ALF=...) which lies outside the permissible range (permissible value range: 0 to 8) was pro-
grammed .
With active cutter radius compensation:
Code numbers 2, 3 and 4 cannot be used in G41
Code numbers 6, 7 and 8 cannot be used in G42 because they code the direction to the contour.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program the lifting direction under ALF=... within the permissible limits.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16005 Channel %1 block %2 invalid value for lifting distance
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Mistake in programming: the value for the lifting path must not be negative.