Cycle alarms
06/2007 Overview of alarms
2-285
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
Remedy: Enter another character.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61185 Channel %1 block %2: no or wrong (min > max) angle areas of rotary
axes agreed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The rotary axis angle range is invalild. Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check installation and start-up of the swivel cycle CYCLE800.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61187 Channel %1 block %2: block search mode not allowed -> select block
search with contour calculation
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select block search with contour calculation.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61191 Channel %1 block %2: 5 axis transformation not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61192 Channel %1 block %2: second 5 axis transformation not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program