Overview of alarms 06/2007
NCK alarms/ISO alarms
2-118
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14022 Channel %1 block %2 error on function or procedure call, error code %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Error code
Definitions: An error occurred during a function or procedure call.
The cause of the error is indicated more closely by an error code.
The meaning of the error code can be found in the documentation of the function or procedure that
caused the error.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14025 Channel %1 block %2 motion synchronous action: illegal modal ID
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In modal motion synchronous actions an illegal ID number has been assigned.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14026 Channel %1 block %2 motion synchronous action: invalid polynomial
number in the FCTDEF command
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An FCTDEF command was programmed with a polynomial number that exceeds the maximum value
set in $MC_MM_NUM_FCTDEF_ELEMENTS.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14027 Channel %1 block %2 motion-synchronous action: Too many technology
cycles programmed.
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: You can call a maximum of eight technology cycles with one motion-synchronous action. You
exceeded the upper limit.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.