Siemens SINUMERIK 802D sl Specifikace Strana 215

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 392
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 214
NCK alarms/ISO alarms
06/2007 Overview of alarms
2-215
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18312 Channel %1 block %2 frame: fine shift not configured
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Fine shift must be configurd with G58 and G59.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify machine data.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18313 Channel %1 block %2 frame: illegal switchover of geometry axes
Parameters: %1 = channel number
%2 = block number, label
Definitions: It is not permissible to change the geometry axis assignment because the current frame contains rota-
tions.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Change NC program or set other mode with MD 10602 FRAME_GEOAX_CHANGE_MODE.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18314 Channel %1 block %2 frame: type conflict
Parameters: %1 = channel number
%2 = block number, label
Definitions: It is not possible to chain global frames and channel-specific frames.
The alarm occurs if a global frame is programmed with a channel axis name and no machine axis is
assigned to the channel axis.
Channel-specific frames cannot be programmed with machine axis names if no corresponding chan-
nel axis is configured for the machine axis.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18400 Channel %1 block %2 language change not possible:%3
Parameters: %1 = channel number
%2 = block number, label
%3 = cause
Definitions: The selection of an external NC language is not possible due to the reason specified. The following
reasons might be specified (see parameter 3):
1. Error in machine data settings
2. Active transformation
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Remedy the specified cause of the error before selecting the language.
Zobrazit stránku 214
1 2 ... 210 211 212 213 214 215 216 217 218 219 220 ... 391 392

Komentáře k této Příručce

Žádné komentáře