06/2007 List of action numbers
3-363
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 122, TEST_SYNC_ASYNC
No. 123, START_LOCK
No. 124, START_UNLOCK
No. 125, FASTMODESWITCHTOAHANDMODE
No. 126, FASTMODESWITCHTOAPROGMODE
Explanation Only for test purposes and only in Assert systems
Cause -
Remedy -
Explanation PI _N_STRTLK Set global start disable
Cause -
Remedy -
Explanation PI _N_STRTUL Reset global start disable
Cause -
Remedy -
Explanation Implicit change of operating mode to Jog at the beginning of a Jog motion in Automatic
mode
See also $MN_JOG_MODE_MASK
Cause 1. A channel has exited the mode group due to an interrupt.
2. Overstore
Remedy − Abort the program with the Reset key or wait until the interrupt is terminated
− Deselect overstore
Explanation Implicit change of operating mode to Automatic at the end of a Jog motion in Automatic
mode
See also $MN_JOG_MODE_MASK
Cause 1. A channel has exited the mode group due to an interrupt.
2. Overstore
Remedy − Abort the program with the Reset key or wait until the interrupt is terminated
− Deselect overstore