06/2007 List of action numbers
3-363
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 122, TEST_SYNC_ASYNC
No. 123, START_LOCK
No. 124, START_UNLOCK
No. 125, FASTMODESWITCHTOAHANDMODE
No. 126, FASTMODESWITCHTOAPROGMODE
Explanation Only for test purposes and only in Assert systems
Cause -
Remedy -
Explanation PI _N_STRTLK Set global start disable
Cause -
Remedy -
Explanation PI _N_STRTUL Reset global start disable
Cause -
Remedy -
Explanation Implicit change of operating mode to Jog at the beginning of a Jog motion in Automatic
mode
See also $MN_JOG_MODE_MASK
Cause 1. A channel has exited the mode group due to an interrupt.
2. Overstore
Remedy Abort the program with the Reset key or wait until the interrupt is terminated
Deselect overstore
Explanation Implicit change of operating mode to Automatic at the end of a Jog motion in Automatic
mode
See also $MN_JOG_MODE_MASK
Cause 1. A channel has exited the mode group due to an interrupt.
2. Overstore
Remedy Abort the program with the Reset key or wait until the interrupt is terminated
Deselect overstore