Overview of alarms 06/2007
NCK alarms/ISO alarms
2-36
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
4350 Channel %1 axis identifier %2 machine data %3 not consistent with
machine data %4
Parameters: %1 = channel number
%2 = string: Axis identifier
%3 = string: MD identifier
%4 = string: MD identifier
Definitions: MD 32410 JOG_AND_POS_JERK_ENABLE (jerk limitation) and MD 35240 ACCEL_TYPE_DRIVE
(acceleration reduction) have been defined as the initial setting for an axis.
However, the two functions cannot be activated at the same time for one axis.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Resetting of 32410
JOG_AND_POS_JERK_ENABLE or MD 35240 ACCEL_TYPE_DRIVE.
Program Con-
tinuation:
Switch control OFF - ON.
4400 MD alteration will cause reorganisation of buffered memory (loss of
data!)
Definitions: An MD has been altered that configures the buffered memory. If the NC powers up with the altered
data, this will lead to reorganization of the buffered memory and thus to the loss of all buffered user
data (part programs, tool data, GUD, leadscrew error compensation, ...).
Reaction: Alarm display.
Remedy: If the control includes user data that has not yet been saved, then a data backup must be performed
before the next NC power-up. By manually resetting the altered MD to the value it had before the last
power-up, reorganization of the memory can be avoided.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
4402 %1 causes a machine data reset
Parameters: %1 = machine data
Definitions: If this machine data is set, the current values of the machine data are overwritten with the pre-set val-
ues on next power up. Under certain circumstances, this can result in loss of data (also in the backed-
up memory).
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. If the control includes user data that has
not yet been saved, then a data backup must be performed before the next NCK power-up. By man-
ually resetting the altered MD to the value it had before the last power-up, reorganization of the mem-
ory can be avoided.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
4502 Channel %1 anachronism %2(%3) -> %4
Parameters: %1 = channel number
%2 = string: MD identifier
%3 = string: MD identifier
%4 = string: MD identifier
Definitions: Previously, in MD 20110 RESET_MODE_MASK Bit4 and Bit5, the reset behavior of the 6th or 8th G
group was determined. This setting is now made in MD 20152 GCODE_RESET_MODE.
In order to ensure compatible handling of "old" data backups, the "old" values are taken from MD
20110 RESET_MODE_MASK and entered in MD 20152 GCODE_RESET_MODE.
Reaction: Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.