Overview of alarms 06/2007
Profibus alarms
2-334
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
Interface signals are set.
Alarm display.
Remedy: NCK restart. If the error cannot be eliminated by this procedure, please make a note of the error text
and contact the control system manufacturer.
Program Con-
tinuation:
Switch control OFF - ON.
380040 PROFIBUS DP: bus %3, configuration error %1, parameter %2
Parameters: %1 = cause of error
%2 = parameter
Definitions: The PROFIBUS DP was not generated in SDB in accordance with the configuration specifications of
the NC in use.
Reaction: Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check that SDB
contains a diagnostic slot for every slave and
only contains slave entries that are relevant to the application.
It is possible to include a superset of slaves in SDB for use in different end versions of the product.
This overloads the NC memory and runtime capacity, however, and should therefore be avoided. If
this alarm occurs, it is necessary to reduce SDB to a minimum.
If the alarm continues to occur, please make a note of the error text and contact the control system
manufacturer.
Program Con-
tinuation:
Switch control OFF - ON.
380050 Profibus-DP: multiple assignment of inputs on address %1
Parameters: %1 = logical address
Definitions: Multiple assignments of input data have been detected in the logical address space.
Logical address: Base address of the address area defined several times
Reaction: Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The address partitioning should be checked as follows:
Check for multiple assignments in the following machine data:
MD 13050[1] - MD 13050[n]n = Largest axis index of control
MD 12970, 12971 PLC address range for digital inputs
MD 12978, 12979PLC address area for analog outputs
If no inconsistencies can be found in the parameters, compare the machine data with the configuration
in SDB. In particular, check that the lengths configured for the individual slots do not result in area
overlaps. When you find the cause of the error, change the machine data and/or SDB.
Program Con-
tinuation:
Switch control OFF - ON.
380051 Profibus-DP: multiple assignment of outputs on address %1
Parameters: %1 = Logical address
Definitions: Multiple assignments of input data have been detected in the logical address space.
Logical address: Base address of the address area defined several times
Reaction: Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The address partitioning should be checked as follows:
Check for multiple assignments in the following machine data:
MD 13050[1] - MD 13050[n]n = Largest axis index of control
MD 12974, 12975 PLC address range for digital outputs
MD 12982, 12983PLC address area for analog outputs