Cycle alarms
06/2007 Overview of alarms
2-287
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61201 Channel %1 block %2: Wrong sequence in machining block
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The sequence of elements in the machining block is invalid.
Alarm triggered by following cycles: E_CP_CE, E_CP_DR, E_MANAGE, F_CP_CE, F_CP_DR,
F_MANAGE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Sort the sequence in the machining block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61202 Channel %1 block %2: No technology cycle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No technology cycle was programmed in the machining block.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program a technology block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61203 Channel %1 block %2: No position cycle
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No positioning cycle was programmed in the machining block.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program positioning block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61204 Channel %1 block %2: Technology cycle unknown
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified technology cycle in the machining block is unknown.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Delete and reprogram the technology block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Komentáře k této Příručce