Siemens SINUMERIK 802D sl Specifikace Strana 286

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 392
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 285
Overview of alarms 06/2007
Cycle alarms
2-286
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61193 Channel %1 block %2: compressor option not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61194 Channel %1 block %2: spline interpolation option not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61197 Channel %1 block %2: no swiveling in JOG --> active WO G%4 and basic
frames contain rotations
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61198 Channel %1 block %2: no swiveling in JOG --> several active basic
frames(G500) contain rotations
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61199 Channel %1 block %2: approach of tool and swivel data record change
(TOOLCARRIER) not allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Zobrazit stránku 285
1 2 ... 281 282 283 284 285 286 287 288 289 290 291 ... 391 392

Komentáře k této Příručce

Žádné komentáře