NCK alarms/ISO alarms
06/2007 Overview of alarms
2-101
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
12480 Channel %1 block %2 subroutine %3 already defined
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: The name used in the PROC or EXTERN instruction has already been defined in another call descrip-
tion (e.g. for cycles).
Example:
EXTERN CYCLE85 (VAR TYP1, VAR TYP2, ...)
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
A program name must be selected that has not yet been used as identifier. (Theoretically, the param-
eter declaration of the EXTERN instruction could also be adapted to the existing subroutine in order
to avoid the alarm output. However, it would have been defined identically twice).
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12481 Channel %1 block %2 program attribute %3 not allowed
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: The attribute used in the PROC instruction is not permitted in the current operating mode.
The attribute SAVE, for example, is not allowed in a technology cycle.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press button NC STOP and select the function "Compensation block" using softkey PROGAM COR-
RECT. The cursor jumps to the incorrect block. Then delete the invalid program attribute.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12490 Channel %1 block %2 access permission level %3 is not valid
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: The required access authorization has not been set. The required protection level lies outside the per-
mitted value range.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
Using the operator panel, set the current protection level to at least the same level as that of the vari-
able with the highest level
Program protection level within the permissible value range
Only program new protection levels that are lower than the old values
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12500 Channel %1 block %2 in this module %3 is not possible
Parameters: %1 = Channel number