NCK alarms/ISO alarms
06/2007 Overview of alarms
2-153
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
15100 Channel %1 block %2 REORG abort caused by log file overflow
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In order to synchronize the preprocessing run and the main run with REORG, the control accesses
modification data which are maintained in a logfile. The alarm indicates that no more capacity is avail-
able in the logfile for the specified block in the channel.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
No remedial measures are available for the further execution of the current NC program, however:
Reduce log file size requirement by:
Reducing the distance between the preprocessing and the main run via appropriate preprocessing
stops STOPRE.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15110 Channel %1 block %2 REORG not possible
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In order to synchronize the preprocessing run and the main run with REORG, the control accesses
modification data which are maintained in a logfile. The alarm indicates that no more capacity is avail-
able in the logfile for the specified block in the channel.
The alarm message means that the logfile has been deleted in order to obtain additional memory for
program reorganization. Consequently, it is no longer possible to REORG the preprocessing memory
up to the next coincidence point.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department.
No remedial measures are available for the further execution of the current NC program, however:
Reduce log file size requirement by:
Reducing the distance between the preprocessing and the main run via appropriate preprocessing
stops STOPRE.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
15120 If a power failure occurs now, data changed before will be lost; buffer
size = %1
Parameters: %1 = Buffer size
Definitions: Notification alarm. The alarm has no negative impact on the current machining.
The system-internal data buffer in which the last buffered data are stored that were changed,
has overflown (as the data change rate is currently too high).
The alarm warns of a spontaneous power failure in this situation
(mains fault, disconnect the system from the power supply) that would cause a loss of
buffered data changed beforehand (tool data, parts programs,
R parameters, GUDs,...
If the system is operated in an environment in which a power failure cannot occur, output of
this alarm can be avoided via machine date $MN_MM_ACTFILESYS_LOG_FILE_MEM = 0.
Parameter %1 informs about the buffer size set.
Reaction: Alarm display.
Remedy: If the alarm is only present sporadically, it can be regarded as a notification only.
The regular control behavior is not influenced.
If the alarm is permanently present, please inform the authorized personnel/service.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.