14017 Channel %1 block %2 syntax error when calling the subroutine via M
function
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: When calling M code subroutine with parameter transfer, an illegal syntax was detected:
Address extension not programmed as a constant.
M function value not programmed as a constant.
Note:
If a parameter transfer has been programmed via MD 10718 M_NO_FCT_CYCLE_PAR for an M
function replacement, the following restriction applies to this M function: both the address extension
and the M function value must be programmed for replacement as constant.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change the programming of the M function.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14018 Channel %1 block %2 parts program command %3 not executable
(protection level setpoint value / actual value: %4)
Parameters: %1 = Channel number
%2 = Block number, Label
%3 = Programmed command
%4 = Protection level of the command
%5 = Current protection level
Definitions: A protection level assigned to the part program command %3 is logically higher (smaller value) than
the current access right or the command does not exist in the current control configuration.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program. The valid language commands for the associated system configuration are
described in the Siemens Programming Guide or the manufacturer’s documentation.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14020 Channel %1 block %2 wrong value or wrong number of parameters on
function or procedure call
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An illegal parameter value was specified in a function or procedure call.
An illegal number of actual parameters was programmed in a function or procedure call.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14021 Channel %1 block %2 wrong value or wrong number of parameters on
function or procedure call
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An illegal parameter value was specified in a function or procedure call.
An illegal number of actual parameters was programmed in a function or procedure call.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Change part program.