Cycle alarms
06/2007 Overview of alarms
2-295
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61244 Channel %1 block %2: Pitch change causing
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified lead change causes a reversal of the thread direction.
Alarm triggered by following cycle: CYCLE99
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check lead change and thread geometry.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61245 Channel %1 block %2: Machining plane does not match modal
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Machining plane does not match modal one.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check the machining plane.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61246 Channel %1 block %2: Safety distance too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The safety clearance is too small for machining.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase safety clearance.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61247 Channel %1 block %2: Blank radius too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The blank radius is too small for machining.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Increase blank radius.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61248 Channel %1 block %2: Infeed too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The infeed is too small for machining.
Alarm triggered by following cycle: CYCLE79.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.